Recessed 6� sloped ceiling LED Non-IC housing for ceilings from 2/12 to
12/12 pitch. The socket aiming mechanism tilts the lamp straight down
regardless of ceiling pitch. Rotational collar allows trim alignment of
up to 20 degree rotation. The HL618 system consists of 1) housing with
integral LED driver, 2) high-efficacy LED light engine with a section
of beam-forming lenses, and 3) slope trim. Housing is suitable for
residential or commercial installations in non-insulated ceilings and
features airtight code compliant construction.
DESIGN FEATURES
1. Housing
�Single wall square aluminum housing construction
�Sealed and gasketed for airtight ASTM-E283 compliance
�Shipped with overspray protector installed
�Mechanism can be removed from the plaster frame to provide access to
the junction box.
�CP - Chicago Plenum model is constructed and gasketed in accordance
with City of Chicago CCEA requirements.
Plaster
Frame
�Galvanized steel frame. Housing adjusts in plaster frame to
accommodate up to 1-3/8� ceiling thickness.
�Regressed locking screw for securing hanger bars.
�Cutouts included for easily crimping hanger bars in position.
�Bar hangers can be repositioned at 90�.
Aiming
Mechanism
�Exclusive socket aiming mechanism tilts and rotates to properly align
the LED light engine.
�LED light engine may be tilted and locked to accommodate 2/12 to 12/12
pitch
�LED light engine and trim may be rotated laterally up to 20 degrees
for compound slope ceilings or to compensate for off-axis aiming
Slide-N-Side�
Junction Box
�Positioned to accommodate straight conduit runs.
�Seven �� trade size conduit knockouts with true pry-out slots.
�Three Slide-N-Side wire traps allow non-metallic sheathed cable to be
without removing knockouts.
�Allows wiring connections to be made outside the box.
�Simply insert the cable directly into the trap after connections are
made.
�Accommodates the following standard non-metallic sheathed cable type:
�U.S. #14/2, #14/3, #12/2, #12/3
�Canada: #14/2, #14/3, #12/2
�Push-wire quick connectors included for field connections.
�CP - Chicago Plenum model features a sealed and gasketed junction box
and flex wireway to meet CCEA requirements. CP model box includes seven
1/2� knockouts (Slide-N-Side feature not available with CP).
GOT NAIL! Pass-N-Thru�
Bar
Hangers
�Captive preinstalled bar hangers adjust to 24� wide
�Housing can be positioned at any point within 24� span
�Pre-installed nail easily installs in regular lumber, engineered
lumber and laminated beams.
�Safety and Guidance system prevents snagging, ensures smooth, straight
nail penetration and allows bar hangers to be easily removed if
necessary
�Automatic leveling flange aligns the housing and allows holding the
housing in place with one hand while driving nails.
�Score lines allow tool-free shortening in narrow joists and bar
hangers do not need to be removed for shortening.
�Bar hangers may be repositioned 90� on plaster frame
�Integral T-bar clip snaps onto T-bars; no additional clips are
required.
LED
Driver
�Integral to the housing, 120V-277V 50/60 Hz universal voltage,
constant current dimmable driver provides high-efficiency operation.
�Driver meets FCC 47CFR Part 15 EMI/RFI consumer limits for use in
residential and commercial installations.
�Driver features high power factor and low THD and has integral thermal
protection in the event of over temperature or internal failure.
�Driver is specifically designed for compatibility with HLM6 LED light
engines.
�If dimming is not required the fixture can be operated from a standard
wall switch.
Dimming
- Phase Control
�Designed for continuous dimming capability to nominally 5% with many
120V Leading Edge (LE) and Trailing Edge (TE) Phase Control dimmers.
(Dimmers with low end trim adjustment offer greater assurance of
achieving 5% level.)
�Consult dimmer manufacturer for compatibility and conditions of use.
(Note some dimmers require a neutral in the wallbox.)
Dimming
- 0-10V
�Dimmable to 10% in typical operation with compatible 0-10V DC low
voltage dimmers.
�0-10V DC dimmers operate using two low voltage dimming wires (color
coded violet and gray). The low voltage dimming wires are separate from
the 120V AC or 277V AC power.
�Switching on/off is controlled via the line voltage (120V AC or 277V
AC) power, and dimming is controlled via the 2-wire 0-10V DC low
voltage wiring.
2. Optical
LED
Light Engines
(Order Separately)
�Exclusively designed for the HL6 slope system, the form-factor and
performance replicate expected PAR lamp qualities in a high lumen LED
light engine
�Turn-to-lock base provides secure retention of the LED light engine to
the aiming mechanism, and provides a low-voltage electrical
quick-connector.
�Proximity phosphors over chip on board LEDs provide a uniform source
with high efficiency and no pixilation.
�See ordering information for available CCT options.
�Passive thermal management achieves L70 at 50,000 hours in IC and
Non-IC applications.
LED
Chromaticity
�A tight chromaticity specification ensures LED color uniformity,
sustainable Color Rendering Index (CRI) and Correlated Color
Temperature (CCT) over the useful life of the LED
�High color performance with 90 CRI minimum, and R9 greater
than 50.
�LED color uniformity of 3 SDCM exceeds ENERGY STAR� color standards
per ANSI C78.377- 2008.
�Every Halo LED is quality tested, measured, and serialized in a
permanent record to register lumens, wattage, CRI and CCT.
�Halo LED serialized testing and measurement ensures color and lumen
consistency on a per-unit basis, and validates long-term product
consistency over time.
3. Beam Forming Lenses
(Interchangeable)
�HLM6 LED light engines are designed to accept HL6 series
lens optics
�The 40-degree Flood (FL) lens is included with the LED light engine,
and may be ordered separately as a replacement
�Alternate beam options are offered in 25-degree Narrow Flood (NFL) and
55-degree Wide Flood (WFL), ordered separately
�The interchangeable lenses feature beam distributions with refined
visual shielding to control beam angle and lumen delivery in
accommodating various ceiling heights.
*Non-IC only, not to be used in direct contact with any type of